Products Description
SL-1104 Overhead Ionizing Air Blower is a special equipment for eliminating static electricity.It belongs to a kind of ion fan series. It has the characteristics of easy installation, stable work, and large range of static elimination. Dedicated ion balancing circuit can achieve automatic ion balancing. The function of SL-1104 four-head suspended ion fan to eliminate static electricity can solve production problems caused by static electricity, such as solving dust washing problems caused by static electricity, bonding problems during the processing of plastic products, and small parts jumping problems caused by electrostatic repulsion.
Overhead Ionizing Air Blower Specification
|
Overhead Ionizing Air Blower |
|
|
Model |
SL-1104A |
|
Operating Voltage |
110v / 60HZ or 220V / 50HZ |
|
Current Consumption |
1.3A or 0.65A |
|
Operating Temperature |
0 ~50°c |
|
Air Volume |
180-420CFM |
|
Air Coverage |
40cm x 120cm |
|
Size |
1100mm (L)×170mm (W)×120mm(H) |
|
Weight |
12kg |
|
Testing Condition: |
||||
|
Operating Voltage: 110V/220V Testing Voltage: 1kV to 100V Temperature: 22℃ |
||||
|
Distance |
300mm |
600mm |
900mm |
1200mm |
|
Left 300mm |
0.6s |
2.1s |
4.9s |
6.1s |
|
Center |
0.6s |
1.9s |
4.2s |
5.7s |
|
Right 300mm |
0.7s |
2.1s |
4.7s |
6.0s |
Products Details
The front cover of the product fuselage adopts the detection and isolation design, which truly and stably detects the unbalanced voltage and isolates the signal of external interference sources

The DC fan is in front and the high-voltage launcher is in rear. The positive and negative ions of high voltage ionization are fully mixed by the fan to better eliminate static electricity.

The back cover of the fuselage has a snap-buckle protection design, which is convenient for disassembling the protective cover to clean the high-pressure launch needle and fan blades.

Built-in power switch, cut off the power immediately after removing the protective cover to ensure the safety of personnel.

Automatic cleaning device, convenient for ion needle maintenance.OEM Support OEM or ODM service provided

SL-1104 Overhead Ionizing Air Blower install
The SL-1104 overhead ionizing air blower is lightweight and has a long service life. The "U"-shaped frame is fixed to the side of the fuselage with screws. When used, it can be positioned in a good position and replaced with M8 diameter plum blossom screws.
If you use it in a particularly dirty environment, you can choose to install the filter.
Slade ion fans require 110V, 60Hz/220, and 50HZ as the operating voltage. The fan grounding socket should be a single-phase standard, and the socket has a safe grounding wire.
The connection method of the power cord is as follows:
Brown-Phase line blue-midline green/yellow-ground line
SL-1104 Overhead Ionizing Air Blower operation
Rotate the governor switch clockwise until the indicator light is on to turn on the fan, generate ion air flow, and adjust the wind speed of the fan. You can rotate the governor switch clockwise and adjust it to the "off" position. The indicator light is off, indicating that the fan is turned off.
To adjust the direction of air flow, you need to loosen the torx screws of the bracket, tilt the fuselage to adjust the upper and lower positions, and then tighten the bracket screws after adjusting.
Clean the ion launcher, rotate the handle of the cleaning head clockwise to stop, and then rotate repeatedly until it is clean.
SL-1104 ion fan generates an ionized wind beam to cover the target area. The time for the wind beam to neutralize static electricity is determined by a variety of factors. The two most important reasons are the distance and wind speed of the ion fan.Air ions are constantly neutralizing each other, and cations and anions attract each other through static electricity, forming the transfer and reorganization of these charges.High wind speeds can neutralize them farther away, and the greater the wind speed, the faster the static electricity can be neutralized.
When using an ion fan for electronic assembly, the ionized air flow should cover the working area as much as possible, so that the positive and negative charges on the surface of the object can be well neutralized and kept in a neutralized state.
Hot Tags: sl-1104 overhead ionizing air blower, China sl-1104 overhead ionizing air blower manufacturers, suppliers, factory















