Products Description
Overhead Ionizing Air Blower is a static elimination device which delivers a balanced ion stream to neutralize wide, focused areas.They remove contaminants attraction and neutralize static charges from wide, focused, or hard-to-reach areas so as to increase productivity in manufacturing. They are ideally used in industrial environments such as delicate electronic products, electronic assembly line, medical device manufacturing and assembly lines, printing, packaging, and small part injection molding etc.
Overhead Ionizing Air Blower Technical Specifications
Overhead Ionizing Air Blower |
|
Model |
SL-002 |
Operating Voltage |
110V/60Hz or 220V/50Hz |
Current Consumption |
0.45A or 0.9A |
Operating Temperature |
0 ~50°c |
Air Volume |
80-220CFM |
Air Coverage |
40cm x 90cm |
Size |
610mm (L)×170mm (W)×125mm(H) |
Weight |
8kg |
Testing Condition: |
||||
Operating Voltage: 110V/220V Testing Voltage: 1kV to 100V Temperature: 22℃ |
||||
Distance |
300mm |
600mm |
900mm |
1200mm |
Left 300mm |
1.3s |
1.9s |
2.5s |
4.2s |
Center |
2.8s |
1.7s |
3.2s |
3.5s |
Right 300mm |
1.1s |
2.3s |
3.4s |
4.5s |
Ionizing Air Blower Features
Effective Static Elimination Provides fast and efficient static charge neutralization.
Wide Coverage Area: Offers extensive coverage, suitable for large work areas and surfaces
Adjustable Airflow: Features adjustable fan speeds to control the airflow, ensuring optimal static elimination for different applications. Equipped with safety features such as visual alarms for high voltage output faults and ion balance adjustments to ensure safe and reliable operation.
Low Noise Operation: Operates with low noise levels, making it suitable for environments where noise control is important.
Overhead Ionizing Air Blower Applications
Overhead Ionizing Air Blower are wildly used in electronics, optoelectronics, semiconductors, plastics, films and printing industries
FAQ
Q: How does an ionizing air blower work?
A: An ionizing air blower works by generating ions that neutralize static charges on surfaces. It uses ionization technology to produce positive and negative ions, which are then blown onto the target area to eliminate static electricity
Q: What are the key technical specifications to consider when choosing an ionizing air blower?
A: When selecting an ionizing air blower, consider the following specifications: Input Voltage: Typically ranges from 100V to 240V AC. Output Voltage: High voltage outputs, often around ±4KV to ±7KV. Power Consumption: Varies by model, but generally low, with some models consuming less than 10W. Ion Balance: Maintains a balance within ±10V to ±30V. Discharge Speed: Fast discharge times, often less than 2.5 seconds. Airflow: Adjustable airflow up to 170 m³/hr (100 cfm) per fan. Noise Level: Low noise operation, typically between 45 dB and 56 dB. Operating Temperature: Suitable for a wide temperature range, usually from 0°C to 50°C. Humidity: Operates in environments with humidity levels up to 70% RH non-condensing.
Q: How do I maintain an ionizing air blower?
A: Regular maintenance is crucial for the effective operation of an ionizing air blower. Key maintenance tasks include: Cleaning the Emitter Tips: Regular cleaning of the emitter tips is necessary to ensure optimal performance. Some models feature automatic cleaning functions. Checking the Air Filters: Ensure that the air filters are clean and free from obstructions. Inspecting the Power Supply: Regularly check the power supply and connections for any signs of wear or damage
Q: Can ionizing air blowers be used in cleanrooms?
A: Yes, many ionizing air blowers are designed for use in cleanrooms and are suitable for ISO class 5 environments. They help maintain a controlled environment by neutralizing static charges and reducing particle adhesion
Q: How do I know if my ionizing air blower is working properly?
A: Most ionizing air blowers come with built-in alarms and indicators that signal any faults or issues. Regularly check the ion balance, discharge speed, and airflow to ensure the device is functioning correctly
Q: How do I install an ionizing air blower?
A: Place the ionizing air blower in the area where static elimination is needed, ensuring it is positioned vertically to the surface that requires static removal. Ensure the ionizer is at least 300mm away from metal conductors and grounded objects. When installing multiple ionizers side by side, maintain a distance of more than 400mm between them and more than 200mm from walls or other obstacles.
ionizing air blower packaging&shipping
1 set/carton
About us
Xiamen qianyu technology co.,ltd.is a professinal cleanroom cleaning products manufacturer,located in Xiamen, China. We buit to provide the most One-stop service for professional cleanroom supplies, from R&D and production to sales. Offers wipes, mats, swabs, and more. We supply cleanroom products to lots of fields. including foodservice,household, medical, personal hygienic, electronic, printing, painting, equipment manufacturing, workplace cleaning & maintenance etc. All procedures are under our control to ensure products′s good quality and high efficiency. Our products have been exported to Europe, South America,Africa,the Middle East,Russia,Southeast Asia and other countries. We have professional engineers, customers can expect the best possible advice and support.
Hot Tags: overhead ionizing air blower, China overhead ionizing air blower manufacturers, suppliers, factory